Types of showers
Contents |
[edit] Introduction
Showers are typically cubicles with a drain at the bottom, and a fixed shower head, or a shower head attached to a flexible hose, that produces a spray of water that allows users to clean themselves.
The Building Regulations Approved Document G: Sanitation, hot water safety and water efficiency suggests that the term ‘sanitary appliance’ means a ‘… WC, urinal, bath, shower, washbasin, sink, bidet and drinking fountain. It also includes appliances that are not connected to a water supply (e.g. composting toilet) or drain (e.g. waterless urinal).’
Showers are available in several different configurations based on factors such as power source, water pressure, water tank capacity, water supply and drainage options, space requirements and so on.
[edit] Water delivery systems
Two types of water delivery systems for showers are instantaneous and mixer.
[edit] Instantaneous showers
Instantaneous showers are generally designed to be connected directly to the mains water supply from the rising main. This type of shower does not require a separate supply of hot water, since incoming water is heated instantly within the device. The hot water is not provided by a central boiler, which means there is less likelihood of a disruption (unless there is a power cut in the case of instantaneous electric showers). The hot water is delivered in a thermostatically controlled manner that is not typically subject to fluctuations.
Most instantaneous showers are electrically powered (although there are some gas powered devices available). The kW rating of an instantaneous electric shower is an indication of the hot water flow - higher ratings are generally associated with better water flow.
In order to operate efficiently, an instantaneous shower must be provided with sufficient water pressure. This may require a shower pump (or booster pump) if the pressure from the mains is inadequate.
[edit] Mixer showers
Mixer showers are connected to pipes that supply hot and cold water. The desired water temperature is achieved by a mixer valve connecter to the shower head. Some shower mixers have a single control to regulate the flow and temperature of the water.
Mixer showers do not generally require electricity to operate unless a pump is needed. Under most conditions, they tend to provide a powerful shower flow as long as the water pressure is adequate.
Thermostatic valves can help to control the water temperature and pressure on mixer showers. If the pressure drops on either the hot or cold supply (perhaps due to an increase in usage elsewhere), the thermostatic valve compensates by adjusting the flow rate to moderate the temperature.
[edit] Shower configurations
A common configuration for a shower is positioned in or above a bathtub.
Alternatively, an independent shower cubicle may be a freestanding, corner installation (or quadrant) or built-in cupboard. These come in various shapes, including square, rectangular, curved, angled and so on.
There are low step and level access showers - as well as wet rooms - that offer accessibility benefits. There are also high end power showers, multi-head body showers, waterfall or rain showers, concealed showers, digital showers and smart showers.
[edit] Related articles on Designing Buildings
- Approved Document G.
- Bath.
- Level access shower.
- Rising main.
- Sanitaryware
- Shower.
- Types of sanitary appliances.
- Water tank.
- Wet room.
[edit] External resources
Featured articles and news
Combating burnout.
The 5 elements of seiri, seiton, seiso, seiketsu and shitsuke.
Shading for housing, a design guide
A look back at embedding a new culture of shading.
The Architectural Technology Awards
The AT Awards 2025 are open for entries!
ECA Blueprint for Electrification
The 'mosaic of interconnected challenges' and how to deliver the UK’s Transition to Clean Power.
Grenfell Tower Principal Contractor Award notice
Tower repair and maintenance contractor announced as demolition contractor.
Passivhaus social homes benefit from heat pump service
Sixteen new homes designed and built to achieve Passivhaus constructed in Dumfries & Galloway.
CABE Publishes Results of 2025 Building Control Survey
Concern over lack of understanding of how roles have changed since the introduction of the BSA 2022.
British Architectural Sculpture 1851-1951
A rich heritage of decorative and figurative sculpture. Book review.
A programme to tackle the lack of diversity.
Independent Building Control review panel
Five members of the newly established, Grenfell Tower Inquiry recommended, panel appointed.
Welsh Recharging Electrical Skills Charter progresses
ECA progressing on the ‘asks’ of the Recharging Electrical Skills Charter at the Senedd in Wales.
A brief history from 1890s to 2020s.
CIOB and CORBON combine forces
To elevate professional standards in Nigeria’s construction industry.
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.